AI Cure is a research tool showing open data. Not medical advice. Discuss with your doctor. Terms

โ† Trials
๐Ÿงช

Hybrid Percutaneous Coronary Intervention Combining a Bioresorbable Scaffold With Drug-coated Balloons Versus a Conventional Drug-eluting Stent-based Strategy in Patients With Long and Diffuse Coronary Artery Disease

RecruitingNAAges 18 Years - anyAllUniversity Hospital, Geneva
๐Ÿ’ฌ

In plain words

What the trial is, and whether it could suit you

The primary objective of the study is to assess the safety and the efficacy of a hybrid percutaneous coronary intervention (PCI) strategy combining a magnesium-based sirolimus-eluting bioresorbable scaffold (Freesolve, Biotronik AG, Switzerland) and โ‰ฅ1 paclitaxel-eluting drug-coated balloon(s) (Pantera Lux, Biotronik AG, Switzerland) compared to a conventional DES-based PCI approach using \>1 newer-generation drug-eluting stents (Orsiro Mission, Biotronik AG, Switzerland) for the treatment of patients with long and/or diffuse coronary artery lesions suitable for PCI with respect to vessel-level absolute change in non-invasive angiography-derived fractional flow reserve (FFRangio, CathWorks, Newport Beach, USA) between post-index PCI and 12-month follow-up. BIOHYBRID is a coronary revascularization strategy study comparing two contemporary treatment approaches for patients with long and/

Sign in to get the eligibility rules as simple questions to take to your doctor.

๐Ÿ“‹ Eligibility rules (as published)
Inclusion criteria: Clinical inclusion criteria 1. Participant is โ‰ฅ18 years. 2. Participant has provided written informed consent as approved by the independent Ethical Committee (EC) or Institutional Review Board (IRB) of the respective participating centre prior to any study-related procedure. 3. Participant is eligible for PCI according to the ESC guidelines (4, 5) . 4. Participant is hemodynamically stable. 5. Participant with chronic coronary syndrome (CCS) or acute coronary syndrome (ACS): unstable angina, non-ST-segment elevation myocardial infarction (NSTEMI), or stabilized ST-segment elevation myocardial infarction (STEMI). 5a. Participants with STEMI are eligible for the treatment of non-culprit coronary lesions, if participant consent occurs โ‰ฅ72 hours after successful primary PCI of the culprit STEMI lesion. 5b. Target lesion(s) to be treated are not located in the STEMI culprit vessel(s) and are not STEMI culprit lesion(s). 6\. Participant is eligible for dual antiplatelet therapy (DAPT) with aspirin plus either clopidogrel, prasugrel, or ticagrelor for โ‰ฅ6 months. 7\. Participant is willing to participate and able to comply with the protocol requirements for the duration of the study, including completion of study visits and control coronary angiogram at 12 months. Angiographic inclusion criteria 8. Target lesion length is \>40 mm according to operator visual estimation, which may be assisted by Quantitative Coronary Angiography (QCA), Intravascular Ultrasound (IVUS), or Optical Coherence Tomography (OCT). 9\. Target vessel has a maximum reference diameter between 3.0-4.6 mm according to operator visual estimation, which may be assisted by QCA, IVUS, or OCT. Notes: The proximal segment, which has a larger vessel diameter, will be treated with one Freesolve scaffold, in accordance with the vessel diameter range specified in the IFU. The distal segment, which naturally tapers to a smaller diameter, can be treated with one or more Pantera Lux DCB, in accordance with the vessel diameter range specified in the IFU. 10\. Target lesion with a baseline (pre-PCI) Thrombolysis In Myocardial Infarction (TIMI) flow โ‰ฅ1. Exclusion criteria: Clinical exclusion criteria 1. Participant has a known allergy to contrast medium that cannot be adequately premedicated, or any known allergy or intolerance to aspirin, P2Y12 receptor inhibitors (clopidogrel, ticagrelor, or prasugrel), both heparin and bivalirudin, any of the following DES or bioresorbable scaffold component (magnesium, aluminium, tantalum, poly-L-lactide, or sirolimus), or drug-coated balloon component (paclitaxel). 2. Participant with STEMI \<72 hours prior to study index procedure. 12a: Participants with hemodynamically stable NSTEMI are eligible for study enrolment. 3. Participant with prior PCI within the target vessel during the last 12 months prior to the study index procedure. 4. Participant is on dialysis or has chronically impaired renal function defined as serum creatinine \>2.5 mg/dL or 221 ฮผmol/L. 5. Participant is unable to adhere to DAPT for at least 6 months (e.g. planned surgery, dental surgical procedure, active bleeding disorders, active coagulopathy). 6. Participant is on oral anticoagulation therapy (OAC) prior to index procedure unless DAPT plus OAC (i.e. triple therapy) can be maintained for a minimum of 1 month. 7. Participant with life expectancy \<1 year. 8. Participant is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study. 9. Participant unwilling or unable (e.g. physical or cognitive) to comply with study procedures, medication adherence and schedule. 10. Contraindications and limitations of the medical devices as described in the instructions for use. 11. Known or suspected non-compliance, drug or alcohol abuse. 12. Inability to follow the procedures of the investigation, e.g. due to language problems, psychological disorders, dementia, etc. of the participant. 13. Participation in another investigation with an investigational drug or another MD within the 30 days prior to enrolment or during participation in the present investigation is generally not permitted. However, co-enrolment in another interventional clinical investigation may be allowed on a case-by-case basis, provided that: * the investigational interventions are scientifically and clinically distinct, the objectives and primary endpoints of the studies are not competing or confounding, * participation is not expected to interfere with participant safety, investigational device performance, or interpretation of the BIOHYBRID study endpoints. Angiographic exclusion criteria 14. Target vessel previously treated with a bare-metal stent or a drug-eluting stent and the target lesion is within 5 mm proximal or distal to the previously treated lesion. 15. Target lesion is a chronic total occlusion. 16. Target lesion is located in left main coronary artery, ostial left anterior descending artery, ostial left circumflex artery, or ostial right coronary artery (within 5.0 mm of the vessel origin). 17. Target lesion is located in, or supplied by, an arterial or venous bypass graft. 18. Target lesion with excessive tortuosity proximal to or within the lesion based on operator visual estimation, or heavily calcified target lesion which may be adequately prepared using a non-compliant and/or cutting/scoring balloon. 19. Target lesion requires treatment with a device other than a non-compliant balloon and/or a modified (cutting/scoring) balloon prior to scaffold/stent placement (including but not limited to atherectomy devices, intravascular lithotripsy). 20. Target lesion involves a coronary bifurcation with a side branch with reference vessel diameter โ‰ฅ2.0 mm that requires a two-device strategy after pre-dilatation. 21. Presence of thrombus in the target vessel. 22. Future planned staged PCI or coronary artery bypass graft surgery after the study PCI procedure. 23. Target with unsuccessful
๐Ÿ’Š

What it tests

  • PCI with a bioresorbable scaffold and drug-coated balloon(s)
  • PCI with drug-eluting stent(s)
๐Ÿ“

Where

4 sites
Geneva University Hospitals
Geneva, Switzerland
Basel University Hospital
Basel, Switzerland
Inselspital
Bern, Switzerland
Zurich University Hospital
Zurich, Switzerland
๐Ÿค Taking part is your choice, and you can leave at any time. Only the trial team can confirm you are eligible โ€” always decide together with your own doctor.
๐Ÿ›ก๏ธ

AI Cure shows public evidence (Open Targets, ClinicalTrials.gov, PubMed, openFDA, DepMap, AlphaFold) with its source, and AI summaries that cite it โ€” not medical advice and not a cure. Treatment decisions belong with your doctor. Research ideas are shared only with approved researchers and labs, who can test them. In an emergency call your local emergency number (112 in India and Europe, 911 in the US). AI Cure Terms of Use ยท Privacy